Page 113 - millerwelds catalog_2022
P. 113

A FLE24 Cat P 113 Safety.qxp_Fume  1/11/24  6:01 PM  Page 1





                                                                               SAFETY AND HEALTH


                   Respiratory



                   SAR Systems                                         SAR (Supplied Air Respirator) systems consist of C50 air regulator, belt assembly,
                                                                       breathing tube, breathing tube cover, flowmeter, tool bag, air hose, and T94i-R helmet
                                                                       assembly (see packages at left).
                                                                        NIOSH 42 CFR 84 certified, assigned protection factor of 25. To provide a NIOSH-
                                                                        approved respiratory system, the SAR with T94i-R must be used with Miller® helmet,
                                                                        hoses, connectors, filters and other components recommended by Miller

                                                                       Well-balanced design reduces torque on neck, increasing all-day wear.
                                                                       Patent-pending Dualtec ™ manifold system optimizes helmet balance and sound, while
                                                                       six-point air distribution system maximizes cooling through targeted air placement.
                      Coiled air hose                                  Ergonomic headgear provides secure fit without the need for over-tightening.
                                                                       Lightweight versatile C50 air regulator can be positioned horizontally or vertically to
                                                                       naturally align with body movements.
                                                                       ClearLight Lens Technology provides high-definition optics for precision arc recognition.
                                                                             ™
                                                                       Shade 5.0 side windows and oversized clear grind shield maximize downward and
                                     Straight                          peripheral visibility, improving sense of surroundings.
                                     air hose
                                                                       Half-shade lens adjustability provides fine shade adjustment for optimized comfort
                                                                       and vision.
                                                                       Large integrated grind shield provides 44 sq. in. of clear viewing area for grinding and
                        ™
                   T94i-R SAR  See literature AY/4.3
                                                                       other tasks.
                          ™
                   With T94i-R helmet (integrated clear grind shield)
                                                                       Enhanced comfort, cooling and visibility maximize all-day wearability — increasing
                   951800  With auto-darkening lens assembly and 25 ft. straight air hose  productivity, safety and regulatory compliance.
                   951801  With auto-darkening lens assembly and 100 ft. straight air hose
                                                                       Low-profile breathing-tube attachment eases on/off process while flexible tube material
                   951802  With auto-darkening lens assembly and 25 ft. coiled air hose
                   951803  With auto-darkening lens assembly and 100 ft. coiled air hose  reduces breathing tube snags in work cell.
                   264871  With auto-darkening lens assembly (air hose not included)  C50 air regulator cools Grade-D breathing air by up to 50 degrees Fahrenheit (28°C)
                                                                       under your hood, heightening productivity and relieving heat stress. Performance under
                   T94i-R ™ helmet upgrade kit (for use with existing SAR system)
                   279871 Includes T94i-R helmet assembly, breathing tube, breathing tube cover   different applications may vary. 360-degree swivel air hose connection alleviates hose
                                                                       coiling, reducing potential trip hazards.
                         and flowmeter
                                                   ™
                                            BreatheAir portable box                    BreatheAir ™ panel
                                            275983  Two person, 10 ppm alarm           275961  Two person, 10 ppm alarm
                    Also                    275985  Four person, 10 ppm alarm          275970  Four person, 10 ppm alarm
                                            Supplies Grade-D breathing air while       Supplies Grade-D breathing air while monitoring for CO.
                    available
                                            monitoring for CO.
                                                                                       Monitor calibration kit
                                            Monitor calibration kit                    275988  10 ppm
                                            275988  10 ppm
                   Half Mask Respirators

                                                                                              ™
                                                   ™
                                             LPR-100 OV                                LPR-100 Half Mask Respirator
                                             Half Mask Respirator                      See literature AY/4.5
                                             See literature AY/4.5                     ML00894  Respirator with P100 filters (small/medium)
                                                                                       ML00895  Respirator with P100 filters (medium/large)
                                             ML00996 Respirator with P100
                                                                                       ML00994  Respirator with P100 nuisance level OV relief
                                                    organic vapor filters
                                                    (small/medium)                                       filters (small/medium)
                                                                                       ML00995  Respirator with P100 nuisance level OV relief
                                             ML00997 Respirator with P100
                                                    organic vapor filters                                filters (medium/large)
                                                    (medium/large)     Filters and accessories
                   Filters and accessories
                                                                       SA00818 P100 filters (one pair)
                   SA00820 P100/OV filters (one pair)
                                                                       SA00819 P100 nuisance level OV relief filters (one pair)
                   285686  Protective hard carrying case
                                                                       283374  Protective hard carrying case
                   261086  Quantitative fit-test kit adapter
                                                                       261086  Quantitative fit-test kit adapter
                                                 ™
                    Low-profile design fits under T94 ™  and Digital Elite welding helmets and
                                                                        Low-profile design fits under T94 ™ , Digital Elite and Classic welding helmets and
                                                                                                  ™
                    provides maximum field of vision                    provides maximum field of vision
                    P100/OV filters provide up to 99.97 percent filtration of specific organic vapors
                                                                        P100 filters provide up to 99.97 percent filtration of airborne particulates
                    and airborne particulates                           Nuisance level OV relief filters are designed for use with organic vapor concentrations
                    NIOSH 42 CFR 84 certified, assigned protection factor of 10
                                                                        not exceeding OSHA’s PELs or other applicable government occupational exposure limits,
                                                                        whichever is lower
                                                                        NIOSH 42 CFR 84 certified, assigned protection factor of 10
                                                                                                                            113
   108   109   110   111   112   113   114   115   116   117   118